tomofix plate Search Results


90
DePuy Synthes angular stable plates tomofix
Angular Stable Plates Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/angular+stable+plates+tomofix/pmc10598142-141-8-12
Average 90 stars, based on 1 article reviews
angular stable plates tomofix - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes titanium plate tomofix
Titanium Plate Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/titanium+rocking+plate+tomofix/pmc05057467-41-4-8
Average 90 stars, based on 1 article reviews
titanium plate tomofix - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes tomofixtm locking compression plate
Tomofixtm Locking Compression Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/tomofix+plate/pmc08901490-142-35-36
Average 90 stars, based on 1 article reviews
tomofixtm locking compression plate - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes tomofix medial high tibial plates and screws
Tomofix Medial High Tibial Plates And Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/tomofix+medial+high+tibial+plate/pm37087428-125-81-91
Average 90 stars, based on 1 article reviews
tomofix medial high tibial plates and screws - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes precontoured titanium medial distal femoral locking plate tomofix
Intraoperative photograph demonstrating the final construct with application of the titanium, <t>precontoured</t> locking plate and complete bony apposition at the site of the osteotomy which is demonstrated by the freer at the site of the osteotomy. In the photograph the supine patient's torso is positioned to the left side of the image.
Precontoured Titanium Medial Distal Femoral Locking Plate Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/medial+tomofix+plate/pmc07823079-42-1-9
Average 90 stars, based on 1 article reviews
precontoured titanium medial distal femoral locking plate tomofix - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes tomofix mdf plate
Intraoperative photograph demonstrating the final construct with application of the titanium, <t>precontoured</t> locking plate and complete bony apposition at the site of the osteotomy which is demonstrated by the freer at the site of the osteotomy. In the photograph the supine patient's torso is positioned to the left side of the image.
Tomofix Mdf Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/tomofix+mdf+plate/pm33355718-36-13-16
Average 90 stars, based on 1 article reviews
tomofix mdf plate - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes locking plate tomofix
Intraoperative photograph demonstrating the final construct with application of the titanium, <t>precontoured</t> locking plate and complete bony apposition at the site of the osteotomy which is demonstrated by the freer at the site of the osteotomy. In the photograph the supine patient's torso is positioned to the left side of the image.
Locking Plate Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/locking+plate+tomofix/pm38738859-47-34-37
Average 90 stars, based on 1 article reviews
locking plate tomofix - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes tomofix™ locking compression plate
Postoperative radiographic measurements. a Standard anterior–posterior radiograph of a right knee after lateral open wedge distal femoral osteotomy using a <t>TomoFix™</t> (DePuy Synthes, Raynham, MA, USA) locking compression plate. b Detailed view of the osteotomy gap with the corresponding measurements. Red dot, osteotomy hinge; AT adductor tubercle (encircled in white); Yellow solid lines, medial–lateral connection of the femoral cortical bone; Yellow dashed line, anatomical axis of the femoral diaphysis, defined as the line connecting the midpoints of the two yellow solid lines; Green line (distance “ a ”), length of the osteotomy gap; Blue line (distance “ b ”), height of the osteotomy gap; Distance “ c ”, horizontal distance between the medial cortical bone and the osteotomy hinge; Distance “ d ”, vertical distance between the proximal margin of the AT and the osteotomy hinge; Distance “ e ”, horizontal distance between the proximal lateral margin of the AT and the osteotomy hinge; *(angle alpha), wedge angle between the proximal and distal osteotomy plane; **(angle beta), slope of the osteotomy defined as the angle between a perpendicular line to the anatomical axis of the femur and the proximal osteotomy plane
Tomofix™ Locking Compression Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/medial+locking+compression+plate+tomofix/pmc08458183-130-34-35
Average 90 stars, based on 1 article reviews
tomofix™ locking compression plate - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes pre-contoured tomofix medial/lateral distal femur plate
Table 2. Return to sports after distal femur osteotomy: surgical technique and complications.
Pre Contoured Tomofix Medial/Lateral Distal Femur Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/tomofix+medial+distal+femur+anatomical+plate/pmc09239358-10-19-24
Average 90 stars, based on 1 article reviews
pre-contoured tomofix medial/lateral distal femur plate - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes plating system tomofix system
Table 2. Return to sports after distal femur osteotomy: surgical technique and complications.
Plating System Tomofix System, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/dual+plating+tomofix+small+version/pmc04752569-62-7-12
Average 90 stars, based on 1 article reviews
plating system tomofix system - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes eight-hole tomofix medial femoral condyle plate
Image 1 shows preoperative valgus lower limb alignment before femoral osteotomy; image 2 shows lower limb alignment after correction using a medial distal femoral plate. Image 3 shows an eight-hole <t>Tomofix</t> (DePuy Synthes) medial femoral condyle plate placed on the medial aspect of the femur, just after the reduction of the osteotomy line
Eight Hole Tomofix Medial Femoral Condyle Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/eight+hole+tomofix+medial+femoral+condyle+plate/pmc08443729-62-4-6
Average 90 stars, based on 1 article reviews
eight-hole tomofix medial femoral condyle plate - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
DePuy Synthes small stature tomofix plate fixator
Image 1 shows preoperative valgus lower limb alignment before femoral osteotomy; image 2 shows lower limb alignment after correction using a medial distal femoral plate. Image 3 shows an eight-hole <t>Tomofix</t> (DePuy Synthes) medial femoral condyle plate placed on the medial aspect of the femur, just after the reduction of the osteotomy line
Small Stature Tomofix Plate Fixator, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix+plate/small+stature+tomofix+plate+fixator/pm38442768-51-52-57
Average 90 stars, based on 1 article reviews
small stature tomofix plate fixator - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Intraoperative photograph demonstrating the final construct with application of the titanium, precontoured locking plate and complete bony apposition at the site of the osteotomy which is demonstrated by the freer at the site of the osteotomy. In the photograph the supine patient's torso is positioned to the left side of the image.

Journal: Arthroscopy Techniques

Article Title: Medial Biplanar Closing-Wedge Distal Femoral Osteotomy Using an Articulated Tensioning Device for Controlled Osteotomy Closure

doi: 10.1016/j.eats.2020.09.010

Figure Lengend Snippet: Intraoperative photograph demonstrating the final construct with application of the titanium, precontoured locking plate and complete bony apposition at the site of the osteotomy which is demonstrated by the freer at the site of the osteotomy. In the photograph the supine patient's torso is positioned to the left side of the image.

Article Snippet: A precontoured titanium medial distal femoral locking plate (TomoFix; DePuy Synthes, Warsaw, IN) is placed at the medial femoral cortex and a fluoroscopic image is taken to estimate the location of the planned osteotomy cut.

Techniques: Construct

Postoperative radiographic measurements. a Standard anterior–posterior radiograph of a right knee after lateral open wedge distal femoral osteotomy using a TomoFix™ (DePuy Synthes, Raynham, MA, USA) locking compression plate. b Detailed view of the osteotomy gap with the corresponding measurements. Red dot, osteotomy hinge; AT adductor tubercle (encircled in white); Yellow solid lines, medial–lateral connection of the femoral cortical bone; Yellow dashed line, anatomical axis of the femoral diaphysis, defined as the line connecting the midpoints of the two yellow solid lines; Green line (distance “ a ”), length of the osteotomy gap; Blue line (distance “ b ”), height of the osteotomy gap; Distance “ c ”, horizontal distance between the medial cortical bone and the osteotomy hinge; Distance “ d ”, vertical distance between the proximal margin of the AT and the osteotomy hinge; Distance “ e ”, horizontal distance between the proximal lateral margin of the AT and the osteotomy hinge; *(angle alpha), wedge angle between the proximal and distal osteotomy plane; **(angle beta), slope of the osteotomy defined as the angle between a perpendicular line to the anatomical axis of the femur and the proximal osteotomy plane

Journal: Knee Surgery, Sports Traumatology, Arthroscopy

Article Title: A hinge position distal to the adductor tubercle minimizes the risk of hinge fractures in lateral open wedge distal femoral osteotomy

doi: 10.1007/s00167-020-06244-6

Figure Lengend Snippet: Postoperative radiographic measurements. a Standard anterior–posterior radiograph of a right knee after lateral open wedge distal femoral osteotomy using a TomoFix™ (DePuy Synthes, Raynham, MA, USA) locking compression plate. b Detailed view of the osteotomy gap with the corresponding measurements. Red dot, osteotomy hinge; AT adductor tubercle (encircled in white); Yellow solid lines, medial–lateral connection of the femoral cortical bone; Yellow dashed line, anatomical axis of the femoral diaphysis, defined as the line connecting the midpoints of the two yellow solid lines; Green line (distance “ a ”), length of the osteotomy gap; Blue line (distance “ b ”), height of the osteotomy gap; Distance “ c ”, horizontal distance between the medial cortical bone and the osteotomy hinge; Distance “ d ”, vertical distance between the proximal margin of the AT and the osteotomy hinge; Distance “ e ”, horizontal distance between the proximal lateral margin of the AT and the osteotomy hinge; *(angle alpha), wedge angle between the proximal and distal osteotomy plane; **(angle beta), slope of the osteotomy defined as the angle between a perpendicular line to the anatomical axis of the femur and the proximal osteotomy plane

Article Snippet: A detailed description of the performed measurements is shown in Fig. . Fig. 1 Postoperative radiographic measurements. a Standard anterior–posterior radiograph of a right knee after lateral open wedge distal femoral osteotomy using a TomoFix™ (DePuy Synthes, Raynham, MA, USA) locking compression plate. b Detailed view of the osteotomy gap with the corresponding measurements.

Techniques:

Table 2. Return to sports after distal femur osteotomy: surgical technique and complications.

Journal: Orthopedic Reviews

Article Title: Return to sport following distal femur osteotomy: a systematic review

doi: 10.52965/001c.33774

Figure Lengend Snippet: Table 2. Return to sports after distal femur osteotomy: surgical technique and complications.

Article Snippet: Voleti et al., 14 2017, USA, Case series , 6 (46%) MCW DFO 7 (54%) LOW DFO , pre-contoured TomoFix medial/lateral distal femur plate (DePuy Synthes) , 9/13 (69%) - 6 LFC OAG - 2 lateral meniscectomy - 1 lateral MAT - 1 ACL revision - 1 patellar tendon debridement - 1 loose body removal , 9/13 (69.2%) - 6 LFC OAG - 2 lateral meniscectomies - 1 meniscus lateral allograft trasplantation - 1 lysis of adhesions and patellar tendon debridement 1 loose body removal , no , 1/13 (7.7%) - 1 hardware removal.

Techniques: Lysis

Image 1 shows preoperative valgus lower limb alignment before femoral osteotomy; image 2 shows lower limb alignment after correction using a medial distal femoral plate. Image 3 shows an eight-hole Tomofix (DePuy Synthes) medial femoral condyle plate placed on the medial aspect of the femur, just after the reduction of the osteotomy line

Journal: Journal of Orthopaedics and Traumatology : Official Journal of the Italian Society of Orthopaedics and Traumatology

Article Title: Medial closure supracondylar femoral osteotomy: an effective solution for long-term treatment of arthritic valgus knee?

doi: 10.1186/s10195-021-00600-z

Figure Lengend Snippet: Image 1 shows preoperative valgus lower limb alignment before femoral osteotomy; image 2 shows lower limb alignment after correction using a medial distal femoral plate. Image 3 shows an eight-hole Tomofix (DePuy Synthes) medial femoral condyle plate placed on the medial aspect of the femur, just after the reduction of the osteotomy line

Article Snippet: Image 3 shows an eight-hole Tomofix (DePuy Synthes) medial femoral condyle plate placed on the medial aspect of the femur, just after the reduction of the osteotomy line All patients involved signed an informed consent, in compliance with the protocol used by the local ethical committee.

Techniques: